标题:plastic granules weighing and mixing system
作者:
日期:2020-05-08 15:07:05
内容:

1.The mixing ratio error refers to the difference between the set percentage and the actual percentage of each component;
2.Gate knife metering valve is suitable for 5% and above ratio, and the mixing ratio error can be controlled within ± 0.3-0.5%;
3.The screw or micrometer is suitable for the ratio of 5% to 0.5%, and the mixing ratio error can be controlled within ± 0.2%;
4.The above maximum processing capacity and mixing ratio error data are data obtained by measuring the continuous operation of uniform raw materials with a bulk density of 0.8 kg / L and a diameter of 3-4 mm. The maximum output will vary according to the number and proportion of the metering group ;
5.Ensure the working pressure of the air valve is 6kgf / cm2;
6.Machine standard voltage specifications: HGB-5 and below models 1ф220V50Hz, HGB-10 and above models 3ф380V50Hz;
7.If customers need to customize special specifications, please contact our company to confirm.
8.Product specifications are subject to change without notice.
plastic granules weighing and mixing system